Received July 11, 2013; Revision Received September 7, 2013; Accepted September 10, 2013.

Abstract

The research is to verify by experiments whether the steel truss structure is able to withstand the load ofcement bricks of upper part of a door for the safe use of lightweight steel truss structure instead of concretelintel which is to be installed at upper part of door frame in building cement bricks for apartment construction.The steel truss is designed in order not to disturb bricks-building and the shape of structure was verified bybending test. According to experiments result, camber was applied to steel structure that enabled constructionwork to be improved and was proved effective for the prevention of accidents by cement bricks-building loadtest.

Reference

1.Architectural Institute of Korea, Architectural Sta ndard Specification, 2006.
2.Kwang-Man Kim, Dong-Myung Hyun, Young- Chun Kim, Strong and Beautiful Construction Story, Baro ConKey Co., Ltd. 1999.
3.KS F 2273, Performance Test of Assembly Panel, 2009.[1] OSHRI. 2009 Industrial Safety & Health Trends Survey, 2010.
4.JSW, “Research on Strength Characteristics by Condition of Cement Matrix Extrusion Material”, Graduate School Master's Degree Thesis, Konkuk University, 1997.
5.KS F 4735, Extrusion Molding Concrete Panel, 2011.
6.Architectural Institute of Korea, B u i l d i n g Structure Standards and Commentary, 2009.
7.MOLIT, Standard Specification for Temporary Work Project, 2006.
  1. SEARCH