A Study on Environmental Impact and Cost Analysis in Electricity Generation Using MFCA For a Coal-fired Power Plant

Byung-Sun Lim*, Seungwook Park*
*Depratment of Sustainability Management, INHA University
Corresponding Author : Seungwook Park,
College of Business Administration, INHA UNIVERSITY, 100, inha-ro, Nam-gu, Incheon,
M․P : 010-4615-2351, E-mail: separk6112@inha.ac.kr
January 04, 2015 March 16, 2015 March 19, 2015

Abstract

Global warming has pressured companies to put a greater emphasis on environment management which allows them to reduce environmental impact and costs of their operations. In Korea, the coal-fired power plants take a large account of electricity generation at 31.7% of the total electricity usage in 2014. Thus, environmental impact of coal-fired power plants is significant. This paper illustrated how to compute environmental impact and costs in electricity generation at a coal-fired power plant using MFCA methodology. Compared to the traditional accounting, an advantage of MFCA is to provide information on electricity generation costs and environmental wastes incurring throughout the production process of electricity. Based on MFCA, the coal-fired power plant was able to reduce production cost of electricity by 52.3%, and environmental wastes by 47.7%. As a result, MFCA seemed to be an effective tool in environmental management for power plants.

MFCA를 적용한 환경부하 및 발전원가 분석 연구 :석탄화력발전소 중심으로

임병선*, 박승욱*
*인하대학교 지속가능경영학과

초록


 

Figure

Table

Reference

  1. SEARCH
  2. Online Submission

    http://submission.koreasafety.or.kr

  3. KSSM

    The Korean Society of Safety ManagementWaste Society

  4. Editorial Office
    Contact Information

    - Tel: +82.31.336.2844
    - Fax: +82.31.336.2845
    - E-mail: safety@mju.ac.kr