A study on the implementation of closed-loop system using the stepper motor back-EMF

Sungbeen Im*·Sanghwa Jeong*
*Dept. of Mechanical Engineering, Chosun University
Corresponding Author: Sanghwa Jeong Dept. of Mechanical Engineering, Chosun University, E-mail: shjeong@chosun.ac.kr

Abstract

In this paper, the control technique of the stepping motor using back electromotive force(B-EMF) without encoder is investigated. The stepping motor generally uses the rotary encoder to detect the rotor position. Since this method increases the cost and the motor configuration size, the new closed-loop control method applied for the B-EMF was implemented by using current detect circuit, AD-converter, and micro controller unit(MCU). The contorl loop of stepping motor became very simplified. The current change of stepping motor measured by the amplifier was measured and analyzed, when the missing step is occurred. Based on the data from current feedback, position errors were compensated and confirmed by using AD-converter.

스텝모터 역기전력을 이용한 폐루프 시스템 구현에 관한 연구

임 성 빈*·정 상 화*
*조선대학교 기계공학과

초록

 

Figure